Mjk-automation Shuttle Ultrasonic Level Transmitter and Sensor Uživatelský manuál Strana 51

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 70
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 50
51
SW 838023
GB Shuttle Manual 100316
Appendix
Shuttle
®
reverts to normal read-out.
mA output signal during system error
This function determines how the mA output should act in
case of a system error.
System errors are most often caused by a weak or missing
ultrasonic echo, but may also occur by failure of the ultra-
sonic sensor or failure in Shuttle
®
's internal circuits.
Select the desired condition with the arrow keys.
The mA output will be locked on the last known value when
a system error occurs.
The mA output will give a fixed signal when a system error
occurs.
Select the desired value (0.35 to 20.5 mA) of the fixed signal
with the arrow keys.
Zobrazit stránku 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 69 70

Komentáře k této Příručce

Žádné komentáře